Vet Immunoassay Cartridge

JIEZLAB Vet Immunoassay Cartridge are designed based on microfluidic technology and used in JIEZLAB Vet Immunoassay Analyzer for veterinary diagnosis. The testing menu includes Canine Thyroid-Stimulating Hormone (cTSH), Total Thyroxine (TT4),Cortisol, Progesterone, Symmetric Dimethylarginine(SDMA),Feline Pancreatic Lipase (fPL), Canine Pancreatic Lipase (cPL). JIEZLAB Vet Immunoassay Cartridge provides rapid, reliable test results to assist veterinarians in medical decisions.

 

The cartridges are stable under 25℃ to ensure the cartridges’ performance even after long transportation. Good detection repeatability CV≤6% satisfies the end-user.

 

Simultaneous detection of multiple different cartridges in a single run enhance the testing efficiency.1

Vet Immunoassay Cartridge

Disease

Test

Applicable Species

Canine Thyroid Diseases

Canine Thyroid-Stimulating Hormone (cTSH)

Canines

Thyroid Diseases

Total Thyroxine (TT4)

Canines and  felines. It also applies to other animal species, including horses, cattle, sheep, birds, etc.

Endocrine Diseases

Cortisol

Canines and  felines. It also applies to other animal species such as horses, cattle, and primates, etc.

Reproductive System Diseases

Progesterone

Canines and  felines. It also applies to other animal species such as livestock, rabbits, guinea pigs, etc.

Renal Function Diseases 

Symmetric Dimethylarginine (SDMA)

Canines and  felines. It also applies to other animal species such as livestock, rabbits, guinea pigs, etc.

Feline Pancreatic Diseases

Feline Pancreatic Lipase (fPL)

Felines

CaninePancreatic Diseases

Canine Pancreatic Lipase (cPL)

Canines

Product characteristics

JIEZLAB

Save sample

50μL whole blood

JIEZLAB

Flexible configuration

Up to 6 samples per run

JIEZLAB

Save Time

Less than 14 minutes

JIEZLAB

High Sensitivity

Good correlation with vet immunoassay gold standard

JIEZLAB

Easy

Calibration through scanning

Procedure

*Note: Gloves must be worn during the whole process to prevent biological hazards and contamination of the reagent disc.

JIEZLAB

01

After removing the reagent disc from refrigerator, allow it to sit at room temperature for 10-15 minutes. It can be used once it has returned to the room temperature

JIEZLAB

02

Scan the QR code on the reagent disk to confirm the testing items

JIEZLAB

03

Pull out the strip
Note: Once the strip is pulled out, the reagent disc must be laid flat and not turned over. Otherwise, the diluent might flow into other chambers

JIEZLAB

04

Add 50-70 μL sample using a pipette to the sample chamber

JIEZLAB

05

Test on the analyzer

Note: When placing the reagent disc, ensure it

aligns with the positioning hole. The reagent

disc should be placed closely against the tray

and kept flat

JIEZLAB

06

Read results